ISAKOS Congress 2021

2021 ISAKOS Biennial Congress ePoster

 

Graft Augmented Osteosynthesis Of Proximal Humerus Fracture In Osteoporotic Fractures

Dr.Neelanagowda V P Patil, MBBS , MS , Mysore, Karnataka INDIA
Arun Gr, MBBS,MS,FASM, Mysore, karnataka INDIA
Ravi G R, MBBS,MS orthopaedics , Mysore, Karnataka INDIA
Manohar Rao H R, MS ORTHOPAEDICS, Bangalore, Karnataka INDIA

Mysore medical college and research institute , Mysore , Karnataka , INDIA

FDA Status Not Applicable

Summary

Proximal Humerus Fractures in Osteoporotic Patients fixed with PHILOS plate along with Fibular Autograft to Prevent Failure and to increase Union rate.

ePosters will be available shortly before Congress

Abstract

Topic :- GRAFT AUGMENTED OSTEOSYNTHESIS OF PROXIMAL HUMERUS FRACTURES IN OSTEOPOROTIC PATIENTS

Introduction

:Fractures of the proximal humerus represent approximately 4% of all fractures and 26% of humerus fractures. A locking plate is currently the most widely used method for fixation of these fractures in both young and elderly patients.The use of Locking plate along with intramedullary autograft is an established technique for these fractures in osteoporotic patients.Our study aimed is to assess the functional and radiological outcome of proximal humerus fractures managed with PHILOS PLATE along with graft and followed them prospectively .

PATIENTS AND METHODS :From June 2019 to May 2021 , 20 patients of proximal humerus fracture with DXA SCAN showing osteoporotic bone were operated with PHILOS plate with auto fibular strut graft were followed prospectively for 6 months duration. The outcomes accessed with VISUAL ANALOGUE SCORE (VAS) ,CONSTANT AND MURLEY SCORING SYSTEM, NECK SHAFT ANGLE , HUMERAL HEAD HEIGHT.

Results

:The mean fracture healing is 18wks and average constant and murley score is 90 points out of 100 points. Superficial Infection was found in 2 patients , stiffness in 1 patient and change in NSA was found in 2 patients with minimal change of 1o degree.

Conclusion

:Graft augmented osteosynthesis provides good bone healing and decreases varus collapse and screw lagout with near normal anatomy like normal range NSA angle and good functional outcome and radiological outcome .