2017 ISAKOS Biennial Congress Paper #262

 

Arthroscopic Superior Capsule Reconstruction Eliminates Pseudoparalysis In Patients with Irreparable Rotator Cuff Tears

Teruhisa Mihata, MD, PhD, Takatsuki, Osaka JAPAN
Thay Q. Lee, PhD, Pasadena, CA UNITED STATES
Akihiko Hasegawa, MD, PhD, Takatsuki, Osaka JAPAN
Takeshi Kawakami, MD, PhD, Osaka City, Osaka JAPAN
Kunimoto Fukunishi, MD, Takatsuki, Osaka JAPAN
Yukitaka Fujisawa, MD, PhD, Kishiwada, Osaka JAPAN
Yasuo Itami, MD, PhD, Takatsuki, Osaka JAPAN
Mutsumi Ohue, MD, Kishiwada, JAPAN
Masashi Neo, MD, PhD, Prof., Takatsuki, Osaka JAPAN

Osaka Medical College, Takatsuki, Osaka, JAPAN

FDA Status Not Applicable

Summary

Arthroscopic SCR improved shoulder function and achieved superior stability in patients with previously irreparable rotator cuff tears both with and without pseudoparalysis.

Abstract

Introduction

We have developed the superior capsule reconstruction (SCR) technique for surgical treatment of irreparable rotator cuff tears. In these patients, SCR restores shoulder stability and muscle balance, consequently improving shoulder function—particularly deltoid muscle function—and relieving pain. In this study, we evaluated whether arthroscopic SCR reversed preoperative pseudoparalysis in patients with irreparable rotator cuff tears.

Methods

A series of 100 consecutive patients with irreparable rotator cuff tears that had failed conservative treatment underwent arthroscopic SCR using fascia lata autografts; 7 patients with deltoid weakness due to cervical or axillary nerve palsy and 3 patients with severe shoulder stiffness (passive shoulder elevation, less than 90°) before surgery were excluded from the study population. The remaining 90 patients were allocated into 3 groups according to their preoperative active shoulder elevation: (1) no pseudoparalysis: more than 90° of active shoulder elevation (48 patients; mean age, 66.3 years; mean tear size in anterioposterior direction, 3.5 cm); (2) moderate pseudoparalysis: no shoulder stiffness, less than 90° of active shoulder elevation, patients maintained more than 90° elevation once the shoulder was elevated passively (27 patients; mean age, 68.1 years, mean tear size, 3.5 cm); and (3) severe pseudoparalysis: no shoulder stiffness, less than 90° of active shoulder elevation, patients had a positive drop-arm sign (15 patients; mean age, 62.3 years, mean tear size, 4.9 cm). Physical examination, radiography, and magnetic resonance imaging were performed before surgery; at 3, 6, and 12 months after surgery; and yearly thereafter. The American Shoulder and Elbow Surgeons (ASES) score, active shoulder range of motion, acromiohumeral distance, and healing rate were compared between patients with and without pseudoparalysis as well as between before surgery and at the final follow-up (mean, 48 months; range, 24 to 88 months) by using the t and chi-square tests. A significant difference was defined as P < 0.05.

Results

ASES score, active elevation, active external rotation, and acromiohumeral distance increased significantly after arthroscopic SCR in patients with no pseudoparalysis, moderate pseudoparalysis, or severe pseudoparalysis. The graft healing rate was 96% (43 of 45) in patients with no pseudoparalysis, 96% (26 of 27) in those with moderate pseudoparalysis, and 87% (13 of 15) in the severe pseudoparalysis group. Postoperative ASES score, active elevation, active external rotation, acromiohumeral distance, and healing rate did not differ among the 3 patient groups. Pseudoparalysis was reversed in 96% (26 of 27) of patients with moderate pseudoparalysis and in 93% (14 of 15) patients with severe pseudoparalysis. Patients with residual moderate or severe pseudoparalysis had graft tears postoperatively.

Conclusion

Arthroscopic SCR improved shoulder function and achieved superior stability in patients with previously irreparable rotator cuff tears both with and without pseudoparalysis. Providing that the graft did not tear postoperatively, arthroscopic SCR reversed preoperative pseudoparalysis. The graft healing rate after arthroscopic SCR did not differ between patients with and without pseudoparalysis.